VISIT OUR YOUTUBE CHANNEL FOR INSTRUCTIONS AND NEWS

Home 9 Products 9 VFD 9 G200
G200_family_dropshadow

PERFORMANCE WITH EASE

G200 Series

G200 Series VFD

Available in

0.5-3HP 240V
1-15HP 480V
1 & 3-PHASE INPUT
3-PHASE INPUT

Available in

0.5-3HP 240V
1-15HP 480V
1 & 3-PHASE INPUT
3-PHASE INPUT

FEATURES

The G200 series is a industrial duty inverter that can be used for a wide range of applications. The G200’s air duct design, hardware configuration, and software capabilities all greatly improve the adaptability along with user friendliness. Additionally, the G200 series uses vectorized V/F control technology to deliver excellent performance with little-to-no maintenance.

 

  • Air-cooling technology implemented
  • Compact design with the option of parallel installation
  • External keypad used to change input/output settings easily
  • QR Code Display for Additional Parameter Information and Fault Troubleshooting
  • DC injection, dynamic, and flux braking
  • Modbus Communication protocol standard (Standard 485 communication interface)
  • Integrated PID controller
  • Open-loop sensorless vector
  • Real-time accumulative power consumption display
  • Built-in standard keypad

Power

Voltage 120V, 240V, 460V
Phase 1-Phase, 3-Phase
Horse Power 1 to 15HP
Input Frequency 50 or 60Hz
Output Frequency 0 to 400Hz
Overload Rating 150% (60 sec)

Features

Braking Unit DC injection, dynamic, flux, and short-circuit braking compatibility built-in for 480V (≤40Hp)
EMI Filter C3
PID Functions Yes
32-Bit DSP Processor Yes
Short-Circuit Braking Yes
Control Mode Sensorless Vector Control, Vector Control

Communications

Communication Protocol PROFIBUS, MODBUS,  MODBUS RTU
Optional Communication Ethernet I/P, MODBUS TCP, BACnet IP, Profinet IO, BACnet MSTP, Metasys N2, FLN, DMX-512, CC-Link, SLMP, MELSEC, AB CSP

Hardware

Analog Input Two programmable analog inputs, 0-10VDC/0-20mA/4-20mA (AI2, AI3)
Analog Output One programmable analog output, 0-10VDC/0-20mA/4-20mA (AO1; AO2)
Digital Input Five total 24VDC inputs; one high-frequency pulse input channel (S1 – S4; HDI)
Digital Output One digital output (Y1)
Relay Output Two relay outputs (R01; R02)

Operations

Display Mono LCD (Color LCD Optional)
Mounting Method Wall or Rail Mount
Operating Temperature -10∼50°C, derate above 40°C
Altitude 1000 meters
Enclosure Rating IP20 standard, UL Type 1 rating with conduit kits on select models

Compliance

Standards UL and CUL listed

 

 

Model Number
Voltage Phase Rating Amps at Normal Duty HP at Normal Duty Enclosure Dimensions

Weight

(LBs)

Height Width Depth
G21S0-00025UL-02 120V 1 Phase input – 3 Phase Output 2.5 .5 IP20 7.3 3.2 5.5 2
G21S0-00042UL-02 120V 1 Phase Input – 3 Phase Output 4.2 1 IP20 7.3 3.2 5.5 2
G21S0-00058UL-02 120V 1 Phase Input – 3 Phase Output 5.8 1.5 IP20 7.3 3.2 5.5 2
G22S0-00025UL-02 240V 1 Phase Input – 3 Phase Output 2.5 .5 IP20 6.3 3.2 4.9 2
G22S0-00042UL-02 240V 1 Phase Input – 3 Phase Output 4.2 1 IP20 6.3 3.2 4.9 2
G22S0-00075UL-02 240V 1 Phase Input – 3 Phase Output 7.5 2 IP20 7.28 3.2 5.5 3
G22S0-00100UL-02 240V 1 Phase Input – 3 Phase Output 10 3 IP20 7.28 3.2 5.5 3
G220-00025UL-02 240V 3 Phase Input – 3 Phase Output 2.5 .5 IP20 7.28 3.2 5.5 2
G220-00042UL-02 240V 3 Phase Input – 3 Phase Output 4.2 1 IP20 7.28 3.2 5.5 2
G220-00075UL-02 240V 3 Phase Input – 3 Phase Output 7.5 2 IP20 10 5.75 5.75 7
G220-00100UL-02 240V 3 Phase Input – 3 Phase Output 10 3 IP20 10 5.75 5.75 7
G240-00025UL-02 460V 3 Phase Input – 3 Phase Output 2.5 1 IP20 7.28 3.2 5.5 2
G240-00037UL-02 460V 3 Phase Input – 3 Phase Output 3.7 2 IP20 7.28 3.2 5.5 2
G240-00055UL-02 460V 3 Phase Input – 3 Phase Output 5.5 3 IP20 7.28 3.2 5.5 2
G240-00095UL-02 460V 3 Phase Input – 3 Phase Output 9.5 5 IP20 10 5.75 5.75 7
G240-00140UL-02 460V 3 Phase Input – 3 Phase Output 14 7.5 IP20 10 5.75 5.75 7
G240-00185UL-02 460V 3 Phase Input – 3 Phase Output 18.5 10 IP20 12.6 6.7 7.7 12
G240-00260UL-02 460V 3 Phase Input – 3 Phase Output 26 15 IP20 12.6 6.7 7.1 12

 

Power

Voltage 120V, 240V, 460V
Phase 1-Phase, 3-Phase
Horse Power 1 to 15HP
Input Frequency 50 or 60Hz
Output Frequency 0 to 400Hz
Overload Rating 150% (1 minute for 240V models)

 

Features

Breaking Unit DC injection, dynamic, flux, and short-circuit braking compatibility built-in for 460V (≤40Hp)
EMI Filter C3
PID Functions Yes
32-Bit DSP Processor Yes
Short-Circuit Braking Yes
Control Mode Sensorless Vector Control and Vector Control

 

Communications

Communication Protocol PROFIBUS, MODBUS, and MODBUS RTU
Optional Communication Ethernet I/P
Modbus TCP
BACnet IP 
Profinet IO
BACnet MSTP
Metasys N2
FLN
DMX-512
CC-Link 
SLMP
MELSEC 
AB CSP

 

Hardware

Analog Input Two programmable analog inputs, 0-10VDC/0-20mA/4-20mA
Analog Output One programmable analog output, 0-10VDC/0-20mA/4-20mA
Digital Input Two (AO1, AO2) 0∼10V/0∼20mA
Digital Output Five inputs, two high-frequency pulse input channels

 

Operations

Display Mono LCD (Color LCD Optional)
Mounting Method Wall or Rail Mount
Operating Temperature -10∼50°C, derate above 40°C
Altitude 1000 meters
Enclosure Rating IP20 standard, UL Type 1 rating with conduit kits on select models

 

Compliance

Standards UL and CUL Listed